Marginal Calibration Does Not Compose: Hidden Dependence in Modular Robot Navigation
arXiv:2609.23731v1 Announce Type: new Abstract: Robotic systems are typically composed of multiple independently developed modules that work together to perceive, predict, and act in the environment. Although each module may perform reliably in isolation, composing them does not necessarily preserve uncertainty calibration at the system level. In this work, we show that well-calibrated component interfaces do not necessarily produce calibrated downstream behavior after composition. Using a moving-obstacle prediction pipeline, we demonstrate that position and velocity estimators can each appear well calibrated individually, yet differences in how their error are correlated lead to substantially different estimates of future-state uncertainty. Consequently, assuming independence can make the system either overly confident or unnecessarily conservative, directly influencing downstream planning decisions and safety. Through simulations, we show that modeling the joint covariance restores d