ArrythML: An Autoencoder-Based TinyML Approach for On-Device Arrhythmia Detection on Resource-Constrained Embedded Systems
arXiv:2606.02256v1 Announce Type: new Abstract: Our work presents a method for ECG segmentation and arrhythmia detection using Tiny Machine Learning (TinyML) models for real-time, on-device inference on resource-constrained embedded systems. We develop INT8 quantized autoencoder-based TinyML models with minimal layers and parameters for embedded deployment. These models are evaluated using a custom dataset derived from the MIT-BIH Arrhythmia Database and validated in both PC-based simulations and on-device environments. For the evaluations, over 95,000 ECG segments are processed on an ESP32-S3 microcontroller running the TensorFlow Lite Micro runtime. Post-evaluation, detailed analysis, including annotation-wise and record-wise failure analysis, is conducted to characterize model behavior across diverse ECG morphologies and rhythm patterns and to explain missed detections. In several cases, apparent misclassifications may correspond to early or subtle anomaly patterns labeled as normal